View Cart Checkout empty cart |
Total
|
Enables centralized management via StruxureWare Central.
Reduces utlility costs, generates less heat.
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Customize network shutdown and reboot sequence of connected servers and UPSs.
Provides temporary battery power when the utility power is out.
Customize UPS capabilities with management cards.
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Provides actual kilowatt hours of usage for energy conscious users.
Load | Efficiency |
25% | 97.8% |
50% | 98.4% |
75% | 98.3% |
100% | 98.1% |
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatically starts up the connected equipment upon the return of utility power.
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Warns when a battery is not available to provide backup power.
Provides remote power management of the UPS over the network.
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
Quickly understand unit and power status with visual indicators.
Provides management of the UPS via a serial port.
Provides management of the UPS via a USB port (not available on all models).
Warns when a battery is not available to provide backup power.
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Provides early-warning fault analysis ensuring proactive component replacement.
Enables a quick recovery from overload events.
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Attribute | Value |
---|---|
Power | Output Output Power Capacity 2700 Watts / 3000 VA Max Configurable Power 2700 Watts / 3000 VA Nominal Output Voltage 230V Output Voltage Note Configurable for 220 : 230 or 240 nominal output voltage Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominal Topology Line Interactive Waveform Type Sine wave Input Nominal Input Voltage 230V Input Frequency 50/60 Hz +/- 3 Hz (auto sensing) |
Battery | Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time 3 hour(s) Replacement Battery RBC55 RBC Quantity 1 Power Input Input Connections IEC-320 C20 Schuko CEE 7 / EU1-16P British BS1363A Input voltage range for main operations 160 - 286V Input voltage adjustable range for mains operation 151 - 302V Other Input Voltages 220, 240 |
Interface | SmartSlot, USB |
Design | Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm Control panel Multi-function LCD status and control console Surge energy rating 365 Joules Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 Sustainable Offer Status RoHS Compliant REACH : Contains No SVHCs |
Environmental | Operating Environment 0 - 40 °C Operating Relative Humidity 0 - 95% Operating Elevation 0-3000 meters Storage Temperature -15 - 45 °C Storage Relative Humidity 0 - 95% Storage Elevation 0-15000 meters Audible noise at 1 meter from surface of unit 53.00 dBA Online Thermal Dissipation 375.00 BTU/hr |
Product can be returned within 48 hours of delivery