Reduces utlility costs, generates less heat.
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
Provides temporary battery power when the utility power is out.
Prolongs battery life by regulating the charge voltage according to battery temperature.
Curve fit to measured runtime data. All measurements taken with new, fully charged batteries, at typical environmental conditions, with no electrical input and balanced resistive load (PF = 1.0) output.
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Automatically starts up the connected equipment upon the return of utility power.
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Warns when a battery is not available to provide backup power.
Provides remote power management of the UPS over the network.
Actively let you know if the unit is on battery, if the battery is low or if there is an overload condition.
Quickly understand unit and power status with visual indicators.
Provides management of the UPS via a serial port.
Provides management of the UPS via a USB port (not available on all models).
Warns when a battery is not available to provide backup power.
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Provides early-warning fault analysis ensuring proactive component replacement.
Enables a quick recovery from overload events.
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Attribute | Value |
---|---|
Power | Output Output Power Capacity 900 Watts / 1500 VA Max Configurable Power 900 Watts / 1500 VA Nominal Output Voltage 230V Output Voltage Distortion Less than 5% at full load Output Frequency (sync to mains) 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominal Topology Line Interactive Waveform Type Sine wave Output Connections (8) IEC 320 C13 IEC 320 C13 (2) IEC Jumpers Input Nominal Input Voltage 230V Input Frequency 50/60 Hz +/- 3 Hz (auto sensing) Input Connections IEC-320 C14 Input volt |
Battery | Battery Type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof Typical recharge time 3 hour(s) Replacement Battery RBC6 RBC Quantity 1 |
Interface | USB |
Design | Audible Alarm Alarm when on battery : distinctive low battery alarm : configurable delays Control panel Multi-function LCD status and control console Surge energy rating 459 Joules Filtering Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449 Conformance-: Regulatory Approvals C-tick, CE, GOST, VDE Sustainable Offer Status-: RoHS Compliant REACH REACH: Contains No SVHCs |
Environmental | Operating Environment 0 - 40 °C Operating Relative Humidity 0 - 95% Operating Elevation 0-3000 meters Storage Temperature -15 - 45 °C Storage Relative Humidity 0 - 95% Storage Elevation 0-15000 meters Audible noise at 1 meter from surface of unit 45.00 dBA Online Thermal Dissipation 135.00 BTU/hr |
Product can be returned within 48 hours of delivery
One Year Warranty